HiPot Test
Category: Testing
Description: HiPot Test checks for "good isolation", ensuring that no current flows between points where there should be no current.
HiPot tests are helpful in finding
nicked or crushed insulation
stray wire strands or braided shielding
conductive or corrosive contaminants around the conductors
terminal spacing problems
tolerance errors in IDC cables
There are three common high voltage tests.
Dielectric Breakdown Test ("How much voltage can I apply between the wires before the insulation fails?"
Dielectric Withstanding Test ("Will this cable withstand a required voltage for a required time?")
Insulation Resistance Test ("Is the resistance of the insulation high enough?")
Process is optional and is turned OFF by default.
Major Cost Drivers -- PCBA HiPot Test
HiPot Test Cycle Time is specific to PCBA design and is therefore entered as a PSO.
Process Time = HiPot Test Time
HiPot Test Time = (PSO)
Hard Tooling Cost = HiPot Test Equipment Cost
HiPot Test Equipment Cost = (PSO)
User Inputs –- PCBA HiPot Test
PSO: HiPot Test Time
PSO: HiPot Test Equipment Cost