Nominal Wall Thickness
Nominal wall thickness is calculated by default, but can be specified by the user (0.10-15.00 millimeters)—see Additional User Inputs. If calculated, the following formula is used:
Nominal Wall Thickness = (2 * Average Wall Thickness + Maximum Wall Thickness) * 1.25/3
Nominal wall thickness is a linear combination of the following:
Part average wall thickness (obtained from required PSO—see Part Surface Area, Projected Area and Perimeter, and Wall Thickness)
Part maximum wall thickness (obtained from required PSO—see Part Surface Area, Projected Area and Perimeter, and Wall Thickness)