Magnetic Penetrant Testing
Magnetic penetrant testing can only be performed on ferromagnetic materials; the material’s cut code must appear in the global lookup table ferromagneticMaterials.
The aPriori Starting Point VPEs define a number of machines for this process.
Cost is based on the following formula:
Process Time = Magnetization Time + Examination Time + Demagnetization Time
Process time is the sum of the following:
Magnetization time (specified by the machine property Magnetization Time—1.5 seconds in aPriori Starting VPEs)
Examination time (calculated as the product of the part surface area and the cost model variable visualInspectTimeStandard--5 min/m2 in aPriori Starting Point VPEs)
Demagnetization time (specified by the machine property Demagnetization Time—30 seconds in aPriori Starting VPEs)